All Germs
Germs

Cryptosporidium parvum

UV doses per log reduction

358101.21D90 · 90 %2.42D99 · 99 %3.63D99.94.84DVGW 4-log6599.999 %7.2699.9999 %mJ/cm²LOG-REDUKTIONS-STUFE

Medium & classification

Water
Protozoan cyst
Test wavelength 268 nm

UV resistance

Sensitive

4.8 mJ/cm² are needed for 4-log reduction — classification for system sizing.

Datenblatt & Quellen

Matsubayashi et al. (2020) Study

Verwandte Inhalte

Similar germs (same type / medium):