All Germs
Germs

Legionella pneumophila

UV doses per log reduction

358101.71D90 · 90 %32D99 · 99 %4.33D99.95.74DVGW 4-log599.999 %699.9999 %mJ/cm²LOG-REDUKTIONS-STUFE

Medium & classification

Water
Bacterium (vegetative)
Size 2000 nm
Test wavelength 254 nm

UV resistance

Sensitive

5.7 mJ/cm² are needed for 4-log reduction — classification for system sizing.

Datenblatt & Quellen

Cerveró-Aragó et al. (2014) Study

Verwandte Inhalte

Similar germs (same type / medium):